Bissoy
Login
Get Advice on Live Video Call
Earn $ Cash $ with
consultations on Bissoy App
Power delivered to load is _________ with an increase in harmonic distortion.
A
Increases
B
Decreases
C
Constant
D
Cannot predict
Correct Answer:
Increases
The equation of output power (Pac)D = Pac (1+D2). It is clear that output power increases with distortion.
Power delivered to load calculated by five-point method can be equal to __________ (Pac is power delivered to load without distortion and D is the RMS of all Harmonic distortion)
A
Pac (1-D2)
B
Pac/D2
C
Pac (1+D2)
D
Pac D2
What is the total harmonic distortion if the amplitude of first harmonic distortion is 20dB and second harmonic distortion 25dB?
A
1.2
B
1.52
C
1.25
D
1.5
What is the total harmonic distortion if the amplitude of first harmonic distortion is 20dB, second harmonic distortion 25dB and external noise is 10dB?
A
11.2dB
B
11.52dB
C
11.25dB
D
11.5dB
Under the condition for 3 phase alternator, maximum active power output, the delivered reactive power output is ________ while under maximum reactive power output, the delivered reactive power is ________
A
negative, negative
B
positive, negative
C
negative, positive
D
positive, positive
If D1, D2, D3, D4 are the distortion produced by second, third, fourth, fifth respectively (others are insignificant). Then total harmonic distortion is __________
A
√(D12+D22+D32+D42)
B
√(D12+D32)
C
√(D22+D42)
D
√(D12+D22)
Calculate the harmonic distortion component for an output signal having a fundamental amplitude of 3 V and a second harmonic amplitude of 0.25 V.
A
3.83%
B
38.3%
C
83.3%
D
8.33%
A harmonic function is analytic if it satisfies the Laplace equation. If u(x, y) = 2x
2
- 2y
2
+ 4xy is a harmonic function, then its conjugate harmonic function v(x, y) is
A
4y<sup>2</sup> - 4xy + constant
B
-4xy + 2y<sup>2</sup> - 2x<sup>2</sup> + constant
C
2x<sup>2</sup> - 2y<sup>2</sup> + xy + constant
D
4xy - 2x<sup>2</sup> + 2y<sup>2</sup> + constant
A step-down delta-star transformer, with per-phase turns ratio of 5 is fed from a 3-phase 1100 V source. The secondary of this transformer is connected through a 3-pulse type rectifier, which is feeding an R load. The power delivered to the load is 6839.3 Watts. The maximum value of the load current is √2 x 22 A. Fin, the rms value of output voltage Vo (rms)
A
257.3 V
B
220 V
C
261.52 V
D
248.32 V
A single phase full bridge inverter circuit, has load R = 2 Ω and dc source Vs = 230 V. Find the value of power delivered to the load in watts only due to the fundamental component of the load current.
A
5361.5 W
B
2142.5 W
C
21424.5 W
D
214.2 W
What is the cause of harmonic distortion in a power amplifier?
A
Exact replication of output signal
B
Perfectly synced harmonics
C
Non-linearity of transistors
D
Linearity of transistors